Customization: | Available |
---|---|
After-sales Service: | 24-Hour Customer Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
XLN Series Counter Flow Closed Circuit Cooling Tower
The XLN Series counterflow closed circuit cooling tower is designed to improve efficiency and reliability. It features a vertical airflow design that maximizes heat exchange efficiency while minimizing footprint. Ideal for industrial applications that require optimal cooling performance, the XLN Series ensures superior performance through its rugged construction and high-quality materials. It can be tailored to specific customer needs and offers customized cooling plans based on detailed operating environments and application scenarios. Dedicated to excellence and cost-effectiveness, the XLN Series sets a new standard in closed-circuit cooling technology.
In 2006, Mr. Luo entered the cooling tower industry, embarking on a long and challenging career. Over the years, he accumulated rich sales and technical experience, gaining deep insights into industry demands and technological trends. With his profound understanding and relentless pursuit of excellence, Mr. Luo garnered widespread recognition and respect within the industry. As time passed, Mr. Luo increasingly felt the limitations of his current work status. Despite significant achievements in technology and sales, he still hadn't fully realized his ideals and ambitions. Concurrently, through years of practice, he came to understand the significant advantages of closed cooling towers over open ones, including higher efficiency, lower maintenance costs, and greater environmental benefits. These advantages revealed to him the immense potential and broad prospects of closed cooling towers in future markets. With a steadfast belief in reshaping the industry's future and his insightful foresight, Mr. Luo decisively founded his own brand of closed cooling towers, XueLun General Machinery Co., Ltd., in 2017. The company's establishment marked a new beginning in Mr. Luo's career, a crucial step towards pursuing his ideals and achieving his ambitions.
Model | Operating Flow Rate (m³/h) |
Cooling Capacity | Water inlet pressure (MPa) |
Inlet and Outlet Pipe Diameter | Fan | Spray Pump | Circulating Pump | External Dimensions | |||||||||||
Kcal/h | Water Inlet (mm) |
Water outlet (mm) |
Drain Outlet (mm) |
Make-Up Water Inlet (mm) |
Power (Kw) |
Qty (set) |
Blowing Rate (m³/h) |
Power (Kw) |
Qty (set) |
Flow Rate (m³/h) |
Pump Lift (m) |
Power (Kw) |
Qty (set) |
Flow Rate (m³/h) |
Pump Lift (m) |
Length*Width*Height(mm) | |||
XLN-6T | 6 | 30,000 | 0--0.3MPa | DN50 | DN50 | DN25 | DN25 | 0.75 | 1 | 10000 | 0.75 | 1 | 22 | 5 | 2.2 | 2 | 11 | 28 | 2400×850×1900 |
XLN-10T | 10 | 50,000 | 0--0.3MPa | DN50 | DN50 | DN25 | DN25 | 0.75 | 1 | 10000 | 0.75 | 1 | 22 | 5 | 2.2 | 2 | 11 | 28 | 2400×850×1900 |
XLN-15T | 15 | 75,000 | 0--0.3MPa | DN65 | DN65 | DN25 | DN25 | 2.2 | 1 | 25000 | 0.75 | 1 | 22 | 5 | 4 | 2 | 25 | 32 | 2700×1230×2500 |
XLN-20T | 20 | 100,000 | 0--0.3MPa | DN65 | DN65 | DN25 | DN25 | 2.2 | 1 | 25000 | 0.75 | 1 | 22 | 5 | 4 | 2 | 25 | 32 | 2700×1230×2500 |
XLN-25T | 25 | 125,000 | 0--0.3MPa | DN65 | DN65 | DN25 | DN25 | 2.2 | 1 | 25000 | 0.75 | 1 | 22 | 5 | 4 | 2 | 25 | 32 | 2700×1230×2500 |
XLN-30T | 30 | 150,000 | 0--0.3MPa | DN65 | DN65 | DN40 | DN25 | 1.5 | 2 | 22000×2 | 1.5 | 1 | 65 | 5 | 4 | 2 | 25 | 32 | 3700×1230×2550 |
XLN-35T | 35 | 175,000 | 0--0.3MPa | DN80 | DN80 | DN40 | DN25 | 1.5 | 2 | 22000×2 | 1.5 | 1 | 65 | 5 | 5.5 | 2 | 46.8 | 28 | 3700×1230×2550 |
XLN-40T | 40 | 200,000 | 0--0.3MPa | DN80 | DN80 | DN40 | DN25 | 1.5 | 2 | 22000×2 | 1.5 | 1 | 65 | 5 | 5.5 | 2 | 46.8 | 28 | 3700×1230×2550 |
XLN-50T | 50 | 250,000 | 0--0.3MPa | DN80 | DN80 | DN40 | DN25 | 1.5 | 2 | 22000×2 | 1.5 | 1 | 65 | 5 | 7.5 | 2 | 50 | 32 | 3700×1400×2550 |
XLN-60T | 60 | 300,000 | 0--0.3MPa | DN80 | DN80 | DN40 | DN25 | 1.5 | 2 | 22000×2 | 1.5 | 1 | 65 | 5 | 7.5 | 2 | 50 | 32 | 3700×1400×2550 |
XLN-70T | 70 | 350,000 | 0--0.3MPa | DN100 | DN100 | DN40 | DN25 | 2.2 | 2 | 25000×2 | 2.2 | 1 | 110 | 5 | 11 | 2 | 93.5 | 28 | 4100×1600×2900 |
XLN-80T | 80 | 400,000 | 0--0.3MPa | DN100 | DN100 | DN40 | DN25 | 2.2 | 2 | 25000×2 | 2.2 | 1 | 110 | 5 | 11 | 2 | 93.5 | 28 | 4100×1600×2900 |
XLN-90T | 90 | 450,000 | 0--0.3MPa | DN100 | DN100 | DN40 | DN25 | 2.2 | 2 | 25000×2 | 2.2 | 1 | 110 | 5 | 11 | 2 | 93.5 | 28 | 4100×1600×3000 |
XLN-100T | 100 | 500,000 | 0--0.3MPa | DN125 | DN125 | DN40 | DN40 | 1.5 | 4 | 22000×4 | 2.2 | 1 | 110 | 5 | 15 | 2 | 100 | 32 | 3500×2000×3000 |
XLN-125T | 125 | 625,000 | 0--0.3MPa | DN125 | DN125 | DN40 | DN40 | 1.5 | 4 | 22000×4 | 2.2 | 1 | 110 | 5 | 15 | 2 | 100 | 32 | 3500×2000×3150 |
XLN-150T | 150 | 750,000 | 0--0.3MPa | DN150 | DN150 | DN40 | DN40 | 4 | 2 | 65000×2 | 4 | 1 | 180 | 5 | 18.5 | 2 | 150 | 28 | 4500×2000×3600 |
XLN-200T | 200 | 1,000,000 | 0--0.3MPa | DN150 | DN150 | DN40 | DN40 | 4 | 2 | 65000×2 | 4 | 1 | 180 | 5 | 30 | 2 | 200 | 32 | 4500×2000×3600 |
XLN-250T | 250 | 1,250,000 | 0--0.3MPa | DN200 | DN200 | DN50 | DN40 | 4 | 4 | 65000×4 | 5.5 | 1 | 230 | 5 | 30 | 2 | 200 | 32 | 5400×3200×3950 |
XLN-300T | 300 | 1,500,000 | 0--0.3MPa | DN250 | DN250 | DN50 | DN40 | 4 | 4 | 65000×4 | 5.5 | 1 | 230 | 5 | 45 | 2 | 320 | 32 | 5400×3200×3950 |
XLN-350T | 350 | 1,750,000 | 0--0.3MPa | DN250 | DN250 | DN50 | DN40 | 4 | 4 | 65000×4 | 7.5 | 1 | 230 | 5 | 55 | _ | _ | _ | 5400×3200×3950 |
Our experienced engineering team tailors cooling solutions to meet specific customer needs.
Innovative Technology
We continuously introduce and apply the latest cooling technologies to enhance product performance and efficiency.
Excellent Quality
Our products are certified under the CSI quality management system.
Stringent Quality Control
Every product undergoes rigorous inspection to ensure 100% factory compliance.
After-sales Service
Professional 24-hour after-sales service is the continuation of our product sales.
Ease of Installation and Maintenance
Our design is with factory module assembly for easy transportation, installation, and maintenance.